When I first used BMW Scanner 1.4 I fell in love from first time use until i started using more and more and i got disappointed with it (Incorrect Index) The old OBDII cable cannot use on cars which was assembled after 2006/03.Īnd Since SOP 2008/09, you must remove pin 8 then you can do everything.” “Since 2006/03, BMW use” Dcan”, means that diagnosis use no KL15, so as GT1, need to change the OBDII cable. Some info got that here is the quote from a BMW thread: 2.20 k+Dcan to work on newer models need to remove pin 8 from obd connector, and that is the difference between 2.0.1 versus 2.20 k+Dcan in function range, coding ant etc. Bmw Inpa K Dcan SoftwareīMW Scanner 2.20 k+Dcan supports the same models, or it support more earlier moddels like 1.4.0. Here I would like to make a comparison between the three popular devices, they are BMW Scanner 1.4.0, BMW Scanner 2.0.1 and BMW Scanner 2.20 K+Dcan. K+DCAN Utility 2.0 Dear all, I have a BMW 2007/06 e87 with D-CAN interface.Įvery BMW owner knows BMW Scanner series, especially BMW Scanner 1.4.0 car diagnostic tool for its low cost and high efficiency, do all kind of stuff including very easy coding.
This need not be scared as they are empty, and are not connected to other components.BMW INPA 5.0.6 download – working ok with K+Dcan cable Decemsales Car Diagnostic Tool, OBD2 Cable 0 BMW INPA 5.0.6 download here, which is tested without issues to work with K+DCAN usb cable with inpa bmw e46 and inpa bmw e90. The board under the flash chip a lot of empty dimes, which are easy to fly off even with careful removal flash. I warn fans to remove the chip, with the ax, nichrome filament, blades, needles, ICOM card in a very delicate and the slightest overheating or attempt to raise the legs lead to the detachment filament tracks. ICOM is loaded, but the program is constantly changing status. In the beginning, all the LEDs flash red on and off. At the first seconds of the boot ICOM, the LED flashes red, but then turns green and ICOM loaded. At boot time, ICOM flashing green LED and is not loaded.
ICOM-BootImage upgrade success, ICOM-ApplicationImage not, at the time of download ICOM LED flashes red. Symptoms of the fall of the flash chip: 1. A sure sign of fall flash chip is a small amount of free space. Very often when you upgrade falls the flash chip K9F2G08U0BPCB0. If you revert failed and the ICOM observed non-standard symptoms, you have to change the flash chip. We wait for about a minute and restart ICOM. All LEDs will light up red and then release the button and press it three times all LEDs flash red. Copy ICOM_Restore.bin to clean flash drive, insert it into the ICOM, press and hold the Reset button on the ICOM, supply it with power.
But before you blow off flash chip, try to roll back using ICOM_Restore.bin file and repeat the update again. If the upgrade process there was a failure at some point or the ICOM does not restart at the end, then you're out of luck and will have to pick up the soldering iron. If you need another IP, edit the file in Notepad ttings, before being copied to a USB flash drive. To assign a standard IP, take a clean USB flash drive and copy the files ttings and, insert the USB flash drive into an available ICOM and wait when the running track will replace the LED color from red to green, and then the flash drive can be removed.
All what you need to recover the firmware of the ICOM is in the archive Restore ICOM.7z. 24 23 If after upgrade, you can not go to the web interface of ICOM, it is likely that the IP has changed.